AIFeed

Probabilistic Monocular Biomechanical Reconstruction via Guided Flow Matching

Summary

arXiv:2611.33809v1 Announce Type: new Abstract: Reconstructing 3D joint kinematics from a single video is ill-posed due to depth and stature ambiguity, limb occlusion, and missing uncertainty estimates. We introduce the Biomechanical Flow Model (BFM), a continuous-time flow-matching prior over subject anthropometry, anatomical joint-angle trajectories, and virtual markers, trained on multi-camera clinical recordings from 565 participants and steered toward monocular 2D keypoints at test time without paired video training. In a head-to-head comparison on the same clinical trials against a state-of-the-art deterministic trajectory optimizer fitting the identical skeleton, BFM achieves comparable joint-angle accuracy across walking and timed-up-and-go (TUG). Across held-out control, prosthetic, and neurologic participants, BFM reaches 3.91 deg and 4.97 deg mean absolute joint-angle error on walking and TUG while providing credible intervals that bridge temporal and whole-limb occlusions.…

Original text(via arXiv cs.CV)

Computer Science > Computer Vision and Pattern Recognition

Title:Probabilistic Monocular Biomechanical Reconstruction via Guided Flow Matching

Abstract:Reconstructing 3D joint kinematics from a single video is ill-posed due to depth and stature ambiguity, limb occlusion, and missing uncertainty estimates. We introduce the Biomechanical Flow Model (BFM), a continuous-time flow-matching prior over subject anthropometry, anatomical joint-angle trajectories, and virtual markers, trained on multi-camera clinical recordings from 565 participants and steered toward monocular 2D keypoints at test time without paired video training. In a head-to-head comparison on the same clinical trials against a state-of-the-art deterministic trajectory optimizer fitting the identical skeleton, BFM achieves comparable joint-angle accuracy across walking and timed-up-and-go (TUG). Across held-out control, prosthetic, and neurologic participants, BFM reaches 3.91 deg and 4.97 deg mean absolute joint-angle error on walking and TUG while providing credible intervals that bridge temporal and whole-limb occlusions. Where keypoints are hidden, the intervals widen with the error and keep their coverage near nominal. Supplying individual anthropometric calibration removes most monocular pelvis depth error, whereas testing on out-of-distribution pediatric crouch gait produces biased, overconfident extension predictions, highlighting the need for pathologically diverse movement priors.
Subjects:Computer Vision and Pattern Recognition (cs.CV)
Cite as:arXiv:2611.33809 [cs.CV]
(or arXiv:2611.33809v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2611.33809 arXiv-issued DOI via DataCite (pending registration)

Submission history

Access Paper:

  • HTML (experimental)

Additional Features

  • Audio Summary

Current browse context:

References & Citations

  • Google Scholar
  • Semantic Scholar

BibTeX formatted citation

Bookmark

Bibliographic and Citation Tools

Code, Data and Media Associated with this Article

Demos

Recommenders and Search Tools

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

The text above was extracted automatically from the source page and may miss images, tables or code blocks. The original is authoritative.

Published by arXiv cs.CV
This site only summarises and aggregates; copyright stays with the original author. Headlines and summaries follow the source — where they differ, the original wins.
Read the original ↗