Summary

arXiv:2611.33392v1 Announce Type: new Abstract: Four-dimensional cone-beam computed tomography (4D-CBCT) images the anatomy of a breathing patient, but sees each breathing phase from only a few angles. Breathing, however, is a smooth motion that repeats; it has a phase. Existing methods exploit this either by reconstructing the anatomy as a function of the breathing phase, often through bins, or by estimating smooth dynamic motions in time. Yet none of these grounds one smooth motion in the phase. We thus propose to share projections across breathing phases with splines. Specifically, we represent the 4D volume with dynamic Gaussians whose motion uses B-splines in space and time. We ground the motion state in the respiratory phase, which we read from well-studied conventional surrogates. Projections at the same phase in different breathing cycles then constrain the same anatomy and motion. On simulated lung scans, our method, BreathSplat, outperforms recent dynamic methods in reconstru…

Original text(via arXiv cs.CV)

Computer Science > Computer Vision and Pattern Recognition

Title:BreathSplat: Grounding One Smooth Motion in the Breathing Phase for 4D Cone-Beam CT

Abstract:Four-dimensional cone-beam computed tomography (4D-CBCT) images the anatomy of a breathing patient, but sees each breathing phase from only a few angles. Breathing, however, is a smooth motion that repeats; it has a phase. Existing methods exploit this either by reconstructing the anatomy as a function of the breathing phase, often through bins, or by estimating smooth dynamic motions in time. Yet none of these grounds one smooth motion in the phase. We thus propose to share projections across breathing phases with splines. Specifically, we represent the 4D volume with dynamic Gaussians whose motion uses B-splines in space and time. We ground the motion state in the respiratory phase, which we read from well-studied conventional surrogates. Projections at the same phase in different breathing cycles then constrain the same anatomy and motion. On simulated lung scans, our method, BreathSplat, outperforms recent dynamic methods in reconstruction and motion accuracy, including those given the ground-truth phase. We further show qualitatively, on two real patient scans, that our method provides clearer reconstructions than the state of the art.
Comments:15 pages, 7 figures
Subjects:Computer Vision and Pattern Recognition (cs.CV)
Cite as:arXiv:2611.33392 [cs.CV]
(or arXiv:2611.33392v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2611.33392 arXiv-issued DOI via DataCite (pending registration)

Submission history

Access Paper:

  • HTML (experimental)

Additional Features

  • Audio Summary

Current browse context:

References & Citations

  • Google Scholar
  • Semantic Scholar

BibTeX formatted citation

Bookmark

Bibliographic and Citation Tools

Code, Data and Media Associated with this Article

Demos

Recommenders and Search Tools

arXivLabs: experimental projects with community collaborators

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

The text above was extracted automatically from the source page and may miss images, tables or code blocks. The original is authoritative.

Published by arXiv cs.CV
This site only summarises and aggregates; copyright stays with the original author. Headlines and summaries follow the source — where they differ, the original wins.
Read the original ↗